Add to Favorites
Share

Pneumatic Chemical Injection Pump

  • Description
Product Detail

    Pneumatic Chemical Injection Pump

    Compressed Air Driven chemical injection pump- DGGDSeries

    We offer the most complete range of Air driven liquid pump models in the industry measured for:

    A.Capability of ultimate pressure, flow or output horsepower. 

    B.Compatibility with a broad variety of liquids, such as oil, water and chemical applications.


    SUNCENTER pumps are air driven at a drive air pressure of 2 to 10bar (29 to145 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.

    Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.


    SUNCENTER pumps are self priming. In general it is not necessary to use an air line lubricator. 

    The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction effect, the inlet check valve is opened and the outlet check valve is closed. The down-stroke generates the pressure at the liquid side. The inlet check valve is closed and the outlet check valve is opened by the generated pressure. SUNCENTER liquid pumps cycle automatically, where the pressure is built up the numbers of cycles slow down, the pump stops automatically when the output pressure forces are equal. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump performance can be affected by a number of conditions, such as freezing of muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air line sizes and dirty filers. Don’t reduce the indicated port sizes and consult SUNCENTER for exact flow conditions not shown in charts.


    Key features include: 

    ·Compressed Air driven - no electricity required (connect to normal air compressor)

    ·In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

    ·No airline lubricator required 

    ·Pressures to 640Mpa (6400 bar)  

    ·Wide range of models with different ratios

    ·Built-in-cooling on most models 

    ·Easy to install, operate and maintain

    ·Best price / performance ratio 

    ·No heat, flame or spark risk and explosion proof 

    ·Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant

    ??14.jpg


    DGGD Series chemical injection pump technical specification

    Model

    Pressure  Boost Ratio

    Driven air pressure PL 

    Formula to calculate outlet pressure

    MAX Outlet
    Pressure

    Liquid inlet Connection

    Liquid outlet Connection

    MAX Flow (L/min)**

    DGGD4

    4:1

    3-8 bar

    4XPL

    32 bar

    NPT1/2

    NPT1/2

    70.00

    DGGD6

    6:1

    3-8 bar

    6XPL

    48 bar

    NPT1/2

    NPT1/2

    48.60

    DGGD10

    10:1

    3-8 bar

    10XPL

    80 bar

    NPT1/2

    NPT1/2

    30.61

    DGGD16

    16:1

    3-8 bar

    16XPL

    128 bar

    NPT1/2

    NPT1/2

    19.73

    DGGD28

    28:1

    3-8 bar

    28XPL

    224 bar

    NPT1/2

    NPT1/2

    11.30

    DGGD40

    40:1

    3-8 bar

    40XPL

    320 bar

    NPT1/2

    NPT3/8

    7.69

    DGGD64

    64:1

    3-8 bar

    64XPL

    512 bar

    NPT1/2

    NPT3/8

    4.94

    DGGD80

    80:1

    3-8 bar

    80XPL

    640 bar

    NPT1/2

    NPT3/8

    3.96

    DGGD100

    100:1

    3-8 bar

    100XPL

    800 bar

    NPT1/2

    NPT3/8

    3.13

    DGGD130

    130:1

    3-8 bar

    130XPL

    1040 bar

    NPT1/2

    M14*1.5

    2.40

    DGGD175

    175:1

    3-8 bar

    175XPL

    1400 bar

    NPT3/8

    M14*1.5

    1.81

    DGGD255

    255:1

    3-8 bar

    255XPL

    2040 bar

    NPT1/4

    M14*1.5

    1.23

    DGGD400

    400:1

    3-8 bar

    400XPL

    3200 bar

    NPT1/4

    M14*1.5

    0.79

    Should the chemical injection pump caters to your requirement, welcome to buy the equipment with our factory. Well-known as one of the professional manufacturers and suppliers, we're equipped with a productive factory to produce the best quality equipment for you.

Send your message to this supplier
To:  

Suncenter Fluid Control Equipment Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>