    Suncenter CO2/oxygen/nitrogen gas booster pump

    Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series 

    Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include: 

    ·Compressed Air driven - no electricity required (connect to normal air compressor)

    ·In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

    ·No airline lubricator required 

    ·Hydrocarbon free - separation between air and gas sections 

    ·Pressures to 80Mpa (11,600 psi)  

    ·Wide range of models with different ratios

    ·Built-in-cooling on most models 

    ·Easy to install, operate and maintain

    ·Best price / performance ratio 

    ·No heat, flame or spark risk and explosion proof 

    ·Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant

    ·Applicable gas: Argon/Helium/Hydrogen/Oxygen/NO2/CH4/LNG/LPG/CNG/FM200 etc.



    Applications 

    ·Pressure test with gas

    ·Gas transfer and filling

    (Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)

    ·Charging of gas cylinder and accumulator with nitrogen

    ·Supply for isolating gas systems

    ·Gas assisted injection molding

    ·Transfer of oxygen cylinders

    ·Charging of breathing air bottles

    ·Leak test 

    ·Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components

    ·Safety valve adjusting 

    DGA series gas booster pumps(Single acting, single air drive head): 

    DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel. 

    ??22.jpg

    Technical spcification

    Model

    Pressure 

    boost ratio

    Min. gas Inlet 

    pressure
    PA (bar)

    Max.gas
    Inlet 

    pressure
    PA (bar)

    Max. gas
    outlet pressure 

    PB (bar)

     

    Driven air pressure  PL

    Formula to
    calculate gas outlet pressure PB

    Connection:
    Gas Inlet /
    Gas outlet (NPT thread)

    Max. flow at driven air pressure of 6bar (L/min)

    DGA02

    2:1

    1.0

    16

    16

    3-8 bar

    2X PL

    1/2 / 1/2

    960 (at PA of 6 bar )

    DGA05

    5:1

    1.5 

    40

    40

    3-8 bar

    5XPL

    1/2 / 1/2

    680(at PA of 6 bar )

    DGA06

    6:1

    2.0

    48

    48

    3-8 bar

    6XPL

    1/2 / 1/2

    360(at PA of 10 bar )

    DGA10

    10:1

    3.5

    80

    80

    3-8 bar

    10XPL

    3/8/ 3/8

    210(at PA of 10 bar )

    DGA25

    25:1

    7.0 

    200

    200

    3-8 bar

    25XPL

    1/4/ 1/4

    120(at PA of 20 bar )

    DGA40

    40:1

    10

    320

    320

    3-8 bar

    40XPL

    1/4/ 1/4

    200(at PA of 40 bar )

    DGA60

    60:1

    20 

    480

    480

    3-8 bar

    60XPL

    1/4/ 1/4

    180(at PA of 40 bar )

    DGA100

    100:1

    25

    800

    800

    3-8 bar

    100XPL

    1/4/ M14X1.5

    136(at PA of 40 bar )

    Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

    In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar


    DGD series gas booster pumps(Double acting ):

    DGD series pumps are double acting, single stage with double air driven heads type.   

    ·DGD pumps are available with high quality seals, which provide significantly better service life

    ·Double pump heads with exhaust cooling devices. 

    ·All components in contact with the gas are made of stainless steel. 

    ·Pipes mounting way are available as customized. 

    ??23.jpg

    Technical specification

    Model

    Pressure 

    boost ratio

    Min. gas

    Inlet 

    pressure
    PA (bar)

    Max.gas
    Inlet 

    pressure
     PA (bar)

    Max. gas
    outlet pressure 

    PB (bar)

     

    Driven air pressure  PL

    Formula to
    calculate gas outlet pressure PB

    Connection:
    Gas Inlet /
    Gas outlet (NPT thread)

    Max. flow at driven air pressure of 6bar (L/min)

    DGD10

    10:1

    3.5

    80

    80

    3-8 bar

    10XPL+ PA

    3/8/3/8

    410(at PA of 6 bar )

    DGD25

    25:1

    10

    200

    200

    3-8 bar

    25XPL+ PA

    1/4/1/4

    396(at PA of 20 bar )

    DGD40

    40:1

    15

    320

    320

    3-8 bar

    40XPL+ PA

    1/4/1/4

    320(at PA of 40 bar )

    DGD60

    60:1

    25

    480

    480

    3-8 bar

    60XPL+ PA

    1/4/1/4

    215(at PA of 40 bar )

    DGD100

    100:1

    35

    800

    800

    3-8 bar

    100XPL+ PA

    1/4/M14*1.5

    300(at PA of 60 bar )

    DGD130

    130:1

    50 

    1040

    1040 

    3-8 bar

    130XPL+ PA

    1/4/M14*1.5

    180(at PA of 60 bar )

    Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

    In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 ba


    DGT series gas booster pumps(Double acting, double stage, single air drive head ):


    DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure. 

    ·DGT pumps are available with high quality seals, which provide significantly better service life 

    ·Double pump heads with exhaust cooling devices. 

    ·All parts in contact with the gas are made of stainless steel.

    ??24.jpg

    Technical specification

    Model

    Pressure 

    boost ratio

    Min. gas
    Inlet 

    pressure
     PA (bar)

    Max.gas
    Inlet 

    pressure
    PA (bar)

    Max. gas
    outlet pressure 

    PB (bar)

     

    Driven air pressure  PL

    Formula to
    calculate gas outlet pressure PB

    Connection:
    Gas Inlet /
    Gas outlet (NPT thread)

    Max. flow at driven air pressure of 6bar (L/min)

    DGT25

    25:1

    1

    10

    200

    3-8 bar

    25XPL+3.5XPA

    3/8/ 1/4

    136(at PA of 8 bar )

    DGT40

    40:1

    1

    10

    320

    3-8 bar

    40XPL+ 6XPA

    3/8/ 1/4

    124(at PA of 8 bar )

    DGT10/60

    10:1/60:1

    1

    10

    480

    3-8 bar

    60XPL+6X PA

    3/8/ 1/4

    84(at PA of 8 bar )

    DGT25/60

    25:1/60:1

    10

    25

    480

    3-8 bar

    60XPL+2.5XPA

    3/8/ 1/4

    80(at PA of 15 bar )

    DGT100

    100:1

    1

    10

    800

    3-8 bar

    100XPL+10XPA

    3/8/ M14*1.5

    63(at PA of 8 bar )

    Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

    In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar

    Should the gas booster pumps caters to your requirement, welcome to buy the equipment with our factory. Well-known as one of the professional manufacturers and suppliers, we're equipped with a productive factory to produce the best quality equipment for you.


    .jpg

     

     

    Suncenter Fluid Control Equipment Co., Ltd is the memeber company of Suncenter Group,which is located in Dongguan city of Guangdong province in China.With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality,competitive price as well as excellent after-sales service, we have win a great reputation in the field.

     

    Our main products including:

    High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)

    High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)

    High Pressure Test Equipment(Hydraulic Pressure Test Machine, Burst/Hydrostatic test machine, Safety Valve Test Bench,Impulse Testing Machine, etc.)

     

     


    If you are interested in any of our products, please feel free to contact us, we could also make the customized products according to your special requirements.

     

     