    Pneumatic (Air compressor driven) gas booster pump system

    ??37.jpg


    Suncenter - Pneumatic gas booster system are compact and delicacy solution tailored to customer specific requirements with gas booster pumps as well as all accessories to be fitted and installed in the frame or a closed cabinet. 

    To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. 

    The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. 

    Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor). 

    Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option. 


    Applications

    ·Pressure test with gas

    ·Gas transfer and filling

    (Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)

    ·Charging of gas cylinder and accumulator with nitrogen

    ·Supply for isolating gas systems

    ·Gas assisted injection molding

    ·Transfer of oxygen cylinders

    ·Charging of breathing air bottles

    ·Leak test 

    ·Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components

    ·Safety valve adjusting


    Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System

    ??38.jpg


    DGS booster system = booster pump+ following valves, gages, and parts


    The hottest selling- model A and model C cabinet picture

    ??40.jpg??41.jpg


    The standard gas booster pumps system including following parts:

    Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

    Stainless steel (carbon steel) material cabinet (Three models for choosing)

    F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

    Driven air switch (Pump starting switch), driven air pressure gauge

    Gas inlet switch, Gas inlet pressure gauge

    Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

    And we could also customize it according to clients’ special requirement.


    Technical specification for DGS-DGA series


    Model

    Pressure 

    boost ratio

    Min. gas
    Inlet 

    pressure
    PA (bar)

    Max.gas
    Inlet 

    pressure
    PA (bar)

    Max. gas
    outlet pressure 

    PB (bar)

     

    Driven air pressure  PL

    Formula to
    calculate gas outlet pressure PB

    Connection:
    Gas Inlet /
    Gas outlet (ZG thread)

    Max. flow at driven air pressure of 6bar (L/min)

    DGS-DGA02

    2:1

    1.0

    16

    16

    3-8 bar

    2XPL

    1/2 / 1/2

    960 (at PA of 6 bar )

    DGS-DGA05

    5:1

    1.5 

    40

    40

    3-8 bar

    5XPL

    1/2 / 1/2

    680(at PA of 6 bar )

    DGS-DGA10

    10:1

    3.5

    80

    80

    3-8 bar

    10XPL

    3/8/ 3/8

    210(at PA of 10 bar )

    DGS-DGA25

    25:1

    7.0 

    200

    200

    3-8 bar

    25XPL

    1/4/ 1/4

    120(at PA of 20 bar )

    DGS-DGA40

    40:1

    10

    320

    320

    3-8 bar

    40XPL

    1/4/ 1/4

    200(at PA of 40 bar )

    DGS-DGA60

    60:1

    20 

    480

    480

    3-8 bar

    60XPL

    1/4/ 1/4

    180(at PA of 40 bar )

    DGS-DGA100

    100:1

    25

    800

    800

    3-8 bar

    100XPL

    1/4/ M14X1.5

    136(at PA of 40 bar )

    DGS-DGA130

    130:1

    35

    800

    1040

    3-8 bar

    130XPL

    1/4/ M14X1.5

    120(at PA of 40 bar )

    Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

    In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar


    Technical specification for DGS-DGD series

    Model

    Pressure 

    boost ratio

    Min. gas
    Inlet 

    pressure
     PA (bar)

    Max.gas
    Inlet 

    pressure
    PA (bar)

    Max. gas
    outlet pressure 

    PB (bar)

     

    Driven air pressure  PL

    Formula to
    calculate gas outlet pressure PB

    Connection:
    Gas Inlet /
    Gas outlet (ZG thread)

    Max. flow at driven air pressure of 6bar (L/min)

    DGS-DGD10

    10:1

    3.5

    80

    80

    3-8 bar

    10XPL+ PA

    3/8/3/8

    410(at PA of 6 bar )

    DGS-DGD25

    25:1

    10

    200

    200

    3-8 bar

    25XPL+ PA

    1/4/1/4

    396(at PA of 20 bar )

    DGS-DGD40

    40:1

    15

    320

    320

    3-8 bar

    40XPL+ PA

    1/4/1/4

    320(at PA of 40 bar )

    DGS-DGD60

    60:1

    25

    480

    480

    3-8 bar

    60XPL+ PA

    1/4/1/4

    215(at PA of 40 bar )

    DGS-DGD100

    100:1

    35

    800

    800

    3-8 bar

    100XPL+ PA

    1/4/M14*1.5

    300(at PA of 60 bar )

    Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

    In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar


    Technical specification for DGS-DGT series

    Model

    Pressure 

    boost ratio

    Min. gas
    Inlet 

    pressure
     PA (bar)

    Max.gas
    Inlet 

    pressure
    PA (bar)

    Max. gas
    outlet pressure 

    PB (bar)

     

    Driven air pressure  PL

    Formula to
    calculate gas outlet pressure PB

    Connection:
    Gas Inlet /
    Gas outlet (ZG thread)

    Max. flow at driven air pressure of 6bar (L/min)

    DGS-DGT25

    25:1

    1

    10

    200

    3-8 bar

    25XPL+3.5XPA

    1/4/ 1/4

    136(at PA of 8 bar )

    DGS-DGT40

    40:1

    1

    10

    320

     

    3-8 bar

    40XPL+ 6XPA

     

    1/4/1/4

    124(at PA of 8 bar )

     DGS-DGT10/60

    10:1/60:1

    1

    10

    480

    3-8 bar

    60XPL+6X PA

     

    1/4/1/4

    84(at PA of 8 bar )

    DGS-DGT25/60

    25:1/60:1

    10

    25

    480

     

    3-8 bar

    60XPL+2.5XPA

     

    1/4/1/4

    80(at PA of 15 bar )

    DGS-DGT100

    100:1

    1

    10

    800

    3-8 bar

    100XPL+10XPA

    1/4/ M14*1.5

    63(at PA of 8 bar )


    Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

    In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar

    Should the gas booster system caters to your requirement, welcome to buy the equipment with our factory. Well-known as one of the professional manufacturers and suppliers, we're equipped with a productive factory to produce the best quality equipment for you.

Send your message to this supplier
To:  

Suncenter Fluid Control Equipment Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>